Hoppa till innehåll
Free shipping over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge broke down overnight – with a WiFi logger, you know before the goods are ruinedThe surface shows one temperature, the core another: why you need both infrared and a probeThe Vernier Caliper That Doesn’t Lose Its Zero When the Battery Is Changed or Coolant SplashesRunout only shows once the probe tip can reach it: how to find 0.01 mm in tight spacesA 10-Metre Wireless Camera Shows Where the Drain Is Blocked Before Anyone Digs Up the FloorAbsolute zero and a rigid frame: how to avoid measurement errors when the part is larger than your vernier caliperThe Air Temperature in the Fridge Doesn’t Tell You How Warm the Vaccine IsWhy you read the deviation and not the dimension when a hundred holes must be checked as carefully as the first oneHow Two Pipe Probes Show Whether Your Heating System Is Really Making Use of the EnergyA core temperature reading in under half a second means the check actually gets doneVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The fridge broke down overnight – with a WiFi logger, you know before the goods are ruinedThe surface shows one temperature, the core another: why you need both infrared and a probeThe Vernier Caliper That Doesn’t Lose Its Zero When the Battery Is Changed or Coolant SplashesRunout only shows once the probe tip can reach it: how to find 0.01 mm in tight spacesA 10-Metre Wireless Camera Shows Where the Drain Is Blocked Before Anyone Digs Up the FloorAbsolute zero and a rigid frame: how to avoid measurement errors when the part is larger than your vernier caliperThe Air Temperature in the Fridge Doesn’t Tell You How Warm the Vaccine IsWhy you read the deviation and not the dimension when a hundred holes must be checked as carefully as the first oneHow Two Pipe Probes Show Whether Your Heating System Is Really Making Use of the EnergyA core temperature reading in under half a second means the check actually gets done

Absolute zero and a rigid frame: how to avoid measurement errors when the part is larger than your vernier caliper

Published 25 November 2026 at 10:15

Many of us have stood with a large part in hand and a vernier caliper that is too short. You end up measuring in two steps, laying a steel rule alongside and estimating the rest. Or you pick up a vernier caliper that has switched itself off, turn it on with the jaws slightly open, and only after three parts do you discover that the zero was wrong. Both situations produce measurement values that look reasonable but are not correct.

Mitutoyo Digimatic digital absolute workshop vernier caliper, measuring range 0-600 mm

What it is

The Mitutoyo Digimatic is a digital workshop vernier caliper with a measuring range of 0-600 mm and a resolution of 0.01 mm. It has front measuring jaws of 90 mm for outside measurement and rear measuring knife-edges of 38 mm for inside measurement. It features buttons for on/off, zero setting and ABS/INC, a locking screw and a Digimatic data output. The accuracy is ±0.05 mm over the full range. Please note that the protection is an ordinary splash guard and that the caliper should not be treated as an IP67 instrument.

What problems it solves

The first is the zero. The caliper has an absolute measuring system, so it knows where it is on the scale even after it has been switched off. An incremental caliper has to be zeroed deliberately every time, and that is a common source of reading errors in the workshop. The second is the frame. On a long vernier caliper, the biggest error is the beam flexing between the jaws when the operator applies pressure. The workshop frame is therefore more rigid than on an ordinary handheld vernier caliper, which keeps the jaws parallel throughout the range.

When it is used

It is used when the part is too large for 150 or 200 mm, but the required accuracy does not justify a large set of outside micrometers. It suits incoming inspection, on-machine checks and final inspection of larger machined parts.

Three use cases

Engineering workshops: Measuring the diameter and length of shafts, rings and flange parts in the 300-600 mm size range without changing instruments or measuring in stages.

Internal grooves and recesses: The ground knife-edges reach into narrow grooves and slots where flat jaws will not fit. The knife-edge length of 38 mm sets the limit for how deep you can measure.

Quality control and documentation: Via the Digimatic output, values can be transferred directly to a computer or a data collection system. This removes manual transcription and the typing errors that come with it.

Why it pays off

The cost of a caliper in this class is recovered through fewer re-measurements, fewer scrapped or wrongly approved parts and less time spent double-checking. A single instrument also replaces several aids when working with large parts. At the same time, it is important to be honest about the limits: with ±0.05 mm, this is a workshop caliper, not a replacement for a micrometer when the tolerance is in hundredths of a millimetre. Choose your instrument based on the tolerance on the drawing.

If you need to measure large parts, both outside and inside, with a zero you can trust, this is a sensible choice for the workshop bench or the inspection station.

Read more

More news

All news