Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The surface shows one temperature, the core another: why you need both infrared and a probeThe Vernier Caliper That Doesn’t Lose Its Zero When the Battery Is Changed or Coolant SplashesRunout only shows once the probe tip can reach it: how to find 0.01 mm in tight spacesA 10-Metre Wireless Camera Shows Where the Drain Is Blocked Before Anyone Digs Up the FloorAbsolute zero and a rigid frame: how to avoid measurement errors when the part is larger than your vernier caliperThe Air Temperature in the Fridge Doesn’t Tell You How Warm the Vaccine IsWhy you read the deviation and not the dimension when a hundred holes must be checked as carefully as the first oneHow Two Pipe Probes Show Whether Your Heating System Is Really Making Use of the EnergyA core temperature reading in under half a second means the check actually gets doneYour probe thermometer is off by 3 °C, and no one noticed until the batch had already been approvedVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The surface shows one temperature, the core another: why you need both infrared and a probeThe Vernier Caliper That Doesn’t Lose Its Zero When the Battery Is Changed or Coolant SplashesRunout only shows once the probe tip can reach it: how to find 0.01 mm in tight spacesA 10-Metre Wireless Camera Shows Where the Drain Is Blocked Before Anyone Digs Up the FloorAbsolute zero and a rigid frame: how to avoid measurement errors when the part is larger than your vernier caliperThe Air Temperature in the Fridge Doesn’t Tell You How Warm the Vaccine IsWhy you read the deviation and not the dimension when a hundred holes must be checked as carefully as the first oneHow Two Pipe Probes Show Whether Your Heating System Is Really Making Use of the EnergyA core temperature reading in under half a second means the check actually gets doneYour probe thermometer is off by 3 °C, and no one noticed until the batch had already been approved

How thick is the wall, really? Measure from one side without cutting open the pipe

Published 13 October 2026 at 20:08

A pipe bend looks a little rusty on the outside, but no one knows how much material is left on the inside. Or a casting where the core has shifted, so that one wall has become thin without anything being visible. With a vernier caliper and a micrometer you can’t get at it, because you can only reach one side. Then you either have to guess, saw the part open or replace it as a precaution.

Digital thickness gauge, ultrasonic principle, standard model with USB data output, tolerance setting with alarm function, memory for 5000 measurements, measuring range 0.65-300 mm

What an ultrasonic thickness gauge does

The instrument sends a 5 MHz ultrasonic pulse through the probe into the material. The pulse is reflected from the back surface, and the gauge calculates the thickness from the time between the transmitted and returning pulse. This means you only need to reach one side. The measuring range is 0.65 to 300 mm with a resolution of 0.1 or 0.01 mm, and the accuracy is ±0.04 mm in the range 0.65 to 9.99 mm. The method is non-destructive, so the part is just as intact after the measurement.

The speed of sound determines the result

Because the thickness is calculated from the speed of sound in the material, the gauge must know which material it is measuring. There are nine preset materials, as well as a mode where you enter the speed of sound yourself, for example from a reference piece of known thickness. This is the only step that requires some thought. If you miss it, all values will be systematically wrong. A drop of couplant between the probe and the surface, which is included in the delivery, provides good acoustic coupling.

Three situations where it is used

Maintenance: Pipes, tanks and pressure vessels corrode from the inside. By measuring at the same points at every shutdown, you get a curve showing how the wall is thinning and can plan the replacement instead of being hit by the leak.

Machine shop industry: After machining castings or thick-walled pipes, you want to know that the minimum wall thickness holds. The tolerance setting with alarm means the operator hears immediately when a value falls outside the limits, without having to read off and calculate.

Food and process industry: Tanks, cooking vessels and piping systems in stainless steel are exposed to wear and cleaning chemicals. Regular thickness measurement provides documented evidence ahead of an audit, without the process having to be opened.

Documentation and economics

The memory holds 5,000 measurements, and via USB you transfer them to a computer for reporting and trend analysis. The instrument operates between -20 and 50 °C, weighs 220 g and is delivered with a factory test report, so it works well out in the plant too. What makes the investment profitable is seldom the measurement itself but what it replaces: unplanned shutdowns, replacement of parts that actually had many years left, and rejects that are only discovered at the customer. A single avoided breakdown or a single saved casting can offset the purchase.

If you need to check wall thickness where you can only reach one side, this is a natural tool to have in your tool trolley. See specifications and accessories on the product page.